This cg drive sk manual, as one of the most working sellers here will agreed be in the midst of the best options to review. cg sk drive parameters / How to install cg drive / Cg drive - sk / cg drive install kese kare Vfd Basics parameter Setting Practical,crompton greaves cg drive sk parameter Setting in hindi. Features of CG Drive - SK. Operation Specifications: Control method selection: Open loop vector control with true space vector modulation: Output frequency range: 0 to Hz: Frequency Resolution: Analog input: Analog I/P resolution is 10Bits i.e.(V/mA) Digital input: Hz: Analog Setting Method: V, mA, V to +10VSM-i/o Lite option. ASD Engineering - Crompton Greaves AC Drives, Danfoss AC Drives solar controller Authorized Wholesale Dealer from Delhi, India ASD Engineering Patparganj, Delhi GST No. 07AWCPPR2ZT.
Crompton Greaves CG Drive-SK, 3-Phase AC Drive, kW to 45 kW Ask Price. Model Name/Number: CG Drive-SK. Motor Power: kW to 45 kW. Input Voltage: V. Input Phase: 3 - Phase. Brand: Crompton Greaves. Output Current: to 83 A. Crompton Greaves VFD - Greaves AC Drive Latest Price. Addendum Emotron FDU/VFX Addendum_Ferrite_Core for Emotron FDU and VFX Addendum-Quick coupling for Liquid cooled Emotron FDU/VFX frame sizes E F (69) Communication settings, Emotron FDU/VFX - Communication settings, Emotron FDU/VFX - sw Emotron VFX Instruction manual. Manual and motorized operating mechanisms can be provided. The reactive crompton greaves motors catalogue dissipation can be lowered by limiting fluxdisturbances and minimizing air gaps in the joints between the core legsand the yokes.
Emotron VSR Solar Drive: kW - kW: VAC, 1 Ph or VDC VAC, 3 Ph or VDC: Pump: IEC: DC Drives: DC Drive Products and Solutions: 20 KW - KW: V DC - V DC: DC Drive system package for process automation in industries like Steel, Cement, Paper, etc. MV Drive: MV Drives: kW - kW: kV to kV. CG Drive-SK. www.doorway.ru kW to 45 kW (HP to 60 HP). V / V. CG Drive -SK. AC Drives Simple to Use,. Compact to Fit, Power to Perform from a Crompton Greaves drive. CG Drive-SK is designed with the same principles to give you an easy to apply Software and Documentation CD included as standard. drive. Frequency given by external potentiometer, start or stop of machine controlled by external switch, control wirings should be as shown below: DI1 AI1 +10V FWD/STOP Potentiometer GND Inverter DI2 REV/STOP GND Figure 4 Control terminal wirings Parameters need to be set as below: b Main frequency source given mode 2: AI1 2.
0コメント